Rated output |
|
Rated current overload |
Rated current 150% 1 minutes |
Voltage |
Three phase 380-440V/220-240V; 50-60Hz |
Power input |
|
Voltage frequency and phase |
Three phase 380-440V, 50/60Hz |
Allow fluctuations |
Voltage: +10-15%, frequency: 5% |
Anti-instantaneous voltage |
310V more continue to operate; dropped below the rated from 310V; continue to operate 15ms
310V above can continue to operate; dropped below the rated from 310V; continue to operate 15ms
160V above can continue to operate; dropped below the rated from 160V; continue to operate 15ms |
Output frequency |
|
The highest frequency |
50-400Hz variable set |
Fundamental frequency |
50-400Hz variable set |
Starting frequency |
50-400Hz variable set |
Carrier frequency |
2-6kHz |
Accuracy |
Setting: 0.3% of maximum frequency set value. No set: setting maximum value of 0.1% frequency |
Resolution |
Setting: erqianfenzhiyi value of the highest frequency setting. Figure: 0.01Hz (99.99Hz below)and 0.1Hz (100Hz more) |
Control |
|
Process control |
PID (proportional standards, integral, differential, closed-loop cotrol) |
Voltage/frequency |
With fundamental frequency can be set 320-440V |
Torque upgrade |
Automatic: according to peak torque value; 0.1-20.0 coding manual setting |
Torque |
More than 150% (torque vector control) |
Canada, deceleration time |
0.1-3600s to accelerate, deceleration time can be set four separate option linear acceleration-decel eration curves |
Subsidiary function |
Frequency limit and the lower frequency control, offset frequency, frequency setting gains, jumping frequency, Restart instantaneous power outage (speed tracking Restart), the current limit |
Transhipment |
|
Functioning operation |
Touch panel: Key operation and stop keys, remote operation. Terminal transformation: the important of instructions, reversw directions and other free operating instructions |
Frequency set |
Touch panel: Eight key, V bond; Terminal input; More choice of frequency, analog signal: DC 0-5V frequency settingdevice or DC 4-20mA |
The operating output |
Centralized alarm output. Open the way for the collector: the choice of operation, frequency of reach and frequency levels, testingor nine separate report. Output: the chice of frequency analog signal, the output current, torque, load rate (0-1mA) |
Show |
|
Digital display (LED) |
Output frequency, output current, output voltage, speed and other operational data |
Liquid crystal display (LCD) |
Operational information, the operator guidance, functional code name of the data, fault information |
HEC instructions (LED) |
Rechargeable, the data show flat touch panel operation instructions, the operating instructions |
Brake |
|
DC brake set |
Brake started frequency (0-60Hz);braking time (0-30s);braking force (0-200% variable set) |
Protection function |
|
Protection function |
Over-current, short circuit, grounding, over voltage, under and overload, overheating electrical over load, external alarm, surge protection devices from the main protection |
Protective casing grades |
|
Protective casing grades |
IP40 IP00 (IP20 so choose) |
Environment |
|
The use of venues |
Indoor, 1000m below sea level, no corrosive gases, dust, direct sunlight |
Temperature/humidity |
- 10 - +50oC/20-90% RH not dewing (22kW over 40oC) in the following specifications |
Vibration |
5.9M/s2 (0.6G) below |
Storage temperature |
applicabletrancporation short-keeping |
Cooling |
|
Cooling |
Forced air cooling |